Bridge Your IT and OT. In Real Time.

Uveous talks directly to your existing PLCs and SCADA systems. Eliminate manual data entry from the shop floor completely. Live OEE, auto yield tracking, and predictive maintenance alerts — all from your machines, automatically.

✓ No Manual Data Entry
⚡ Real-Time OEE Tracking
1
Shop Floor Machines
Sensors, Drives, Motors, Meters
2
Existing PLC / SCADA
Siemens, Rockwell, Delta, Mitsubishi
3
Uveous IoT Gateway
Modbus TCP · OPC-UA · MQTT
4
Uveous ERP Cloud
Live OEE · Auto Yield · AI Alerts

Works With Your Existing Equipment

No expensive hardware replacement required. Our gateway connects to what you already have.

🔌

Modbus RTU

Serial communication with older PLCs and field instruments over RS-485

🌐

Modbus TCP

Ethernet-based real-time data from PLCs and smart meters

🔒

OPC-UA

Secure, standardized machine-to-cloud for Industry 4.0 deployments

📡

MQTT

Lightweight IoT messaging for distributed field devices and edge nodes

🏭

EtherNet/IP

Allen-Bradley and Rockwell PLC communication via CIP tag mapping

⚙️

PROFIBUS

Siemens and legacy automation system integration

🏗️

BACnet

Building and facility management system connectivity

🔗

REST API

Integration with modern smart machines and edge computing devices

Every Major PLC Brand. Natively.

Covering 95%+ of PLCs installed in Indian manufacturing plants today.

🇩🇪

Siemens

S7-300, S7-400, S7-1200, S7-1500 via S7 Protocol, Profinet, and TIA Portal data blocks.

🇺🇸

Allen-Bradley (Rockwell)

CompactLogix, ControlLogix, MicroLogix via EtherNet/IP with native CIP tag mapping.

🇯🇵

Mitsubishi

FX series, Q series, iQ-R series via Modbus TCP and MELSEC communication protocols.

🇫🇷

Schneider Electric

Modicon M340, M580, Momentum via Modbus TCP and Unity Pro integration.

🇹🇼

Delta Electronics

DVP series via Modbus RTU — popular with Indian SME machinery manufacturers.

🇯🇵

Omron

CP, CJ, CS series via FINS/TCP and Modbus TCP protocols with register mapping.

What Uveous Reads From Your Machines

Every data point that matters for production efficiency and predictive maintenance.

Data Point Register Type Used In Business Use Case
Production CountDigital Output CounterMES / ERPOEE Calculation
Machine TemperatureAnalog Input (AI)CMMSPredictive Maintenance Alert
Energy Consumption (kWh)Power Meter RegisterFinance / CMMSEnergy Cost per Unit Produced
Cycle TimeTimer RegisterERP SchedulingBottleneck Identification
Vibration Level (mm/s)Analog InputCMMSBearing Failure Prediction
Motor Current (A)Analog InputCMMSOverload / Winding Fault Detection
Downtime EventAlarm BitCMMS / MESDowntime Analysis
Running HoursCounter RegisterCMMSPM Schedule Trigger

On-Premise Edge Box for Data-Sensitive Plants

For factories with limited connectivity or strict data sovereignty requirements, Uveous offers a DIN-rail mount Edge Box that processes sensor data locally before syncing to cloud.

  • Pre-processes sensor data locally — no cloud latency
  • Operates in offline mode and syncs when connectivity is restored
  • Local alarming even without cloud connection
  • DIN-rail mount format for control panel installation
  • Supports all Modbus, OPC-UA, and MQTT protocols locally
📦

Uveous Edge Box Specs

Form FactorDIN-Rail Mount
Operating Temp-10°C to 60°C
ProtocolsModbus, OPC-UA, MQTT
ConnectivityEthernet + 4G SIM

Ready to Connect Your Machines?

Our automation engineers will assess your existing PLC setup and design a zero-downtime integration plan.

Talk to an Automation Engineer →